Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Arch. cardiol. Méx ; 93(4): 391-397, Oct.-Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527715

ABSTRACT

Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.

2.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Article in English | LILACS | ID: biblio-1249911

ABSTRACT

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Subject(s)
Animals , Male , Female , Rabbits , Paclitaxel/administration & dosage , Sirolimus/administration & dosage , Drug-Eluting Stents , Prosthesis Design , Spectrophotometry, Infrared , Swine , Follow-Up Studies , Disease Models, Animal , Microscopy
3.
Rev. invest. clín ; 72(2): 103-109, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1251841

ABSTRACT

ABSTRACT Background: The left atrial appendage (LAAp) resection is an effective treatment approach to reduce the risk of thromboembolism in patients with atrial fibrillation. Objective: To study was to study the impact of removing atrial appendages in the production of natriuretic peptides (NPs) in conditions of volume overload and to develop an experimental model of LAAp resection. Materials and Methods: In a swine model of ischemic heart failure (HF), serum NP levels were measured before (Basal-1A) and after (Basal-1B) a fluid overload. Animals were grouped as follows: (0) preserved appendages, (1) resected LAAp, and (2) both atrial appendages resected. Levels of NP were measured before (2A) and after a fluid overload (2B). Results: Furin levels were higher in Group 0-2A than in Group 2-2A, and a significant increase was found in Group 0-2B compared to Groups 1-2B and 2-2B. Corin levels increased in Basal-1B versus Basal-1A. Atrial NP (ANP) decreased in Basal-1B compared to Basal-1A. After HF induction, ANP increased in Groups 2-2A and 2-2B. Conclusions: Resection of atrial appendages drastically modifies the natriuretic mechanisms of cardiac homeostasis, especially after a fluid overload challenge. Herein, we describe the face and predictive validation of an animal model of atrial appendage resection useful to investigations in translational medicine.


Subject(s)
Animals , Male , Atrial Appendage/surgery , Atrial Appendage/metabolism , Disease Models, Animal , Heart Failure/surgery , Heart Failure/metabolism , Homeostasis , Swine , Natriuretic Peptides/biosynthesis , Natriuretic Peptides/physiology , Academic Medical Centers
4.
Rev. mex. anestesiol ; 42(1): 28-34, ene.-mar. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1139314

ABSTRACT

Resumen: Objetivo: Conocer si la ketamina a dosis subanestésicas disminuye el dolor agudo, agitación y requerimientos analgésicos en cateterismo cardíaco. Material y métodos: Pacientes de dos meses a siete años, anestesia general, ASA II-IV. Dos grupos: K: ketamina y F: fentanyl más analgésico; sevoflurano 1-1.2 CAM y ventilación mecánica. Registro de signos vitales: basales, inicio del procedimiento y emersión. Valoración con FLACC y Ramsay a la emersión y al llegar a su cama, se administró analgésico con FLACC > 4. Resultados: 121 pacientes, grupo K: 52.8%, grupo F: 47%, edad: 47 ± 26.38 meses, tiempo anestésico: 100.22 ± 38.7 min. Variables cardiovasculares sin diferencia intergrupos en relación al tiempo. Requerimientos analgésicos a las seis horas en grupo K y F hasta las 10 horas. FLACC en emersión leve 86.8%; 49% grupo K y 37% grupo F: (p = 0.02), al llegar a piso FLACC leve 92%, grupo K 52% y 40.4% grupo F (p = 0.002). A las seis horas FLACC > 4 en grupo K (p = 0.002). Grado de sedación a la extubación menor en el grupo K (p = 0.03). Conclusiones: La ketamina preserva estabilidad hemodinámica, disminuye agitación y dolor las primeras seis horas postprocedimiento; se puede utilizar como coadyuvante anestésico seguro.


Abstract: Objetive: Determine if the subanesthetic dose ketamine decreases acute pain, agitation, analgesic requirements in cardiac catheterization. Material and methods: Patients aged two months to seven years, general anesthesia, ASA II-IV. Two groups K: ketamine and F: fentanyl plus painkiller; sevoflurane 1-1.2 CAM and mechanical ventilation. Registration baseline vital signs, the initiation and emergence. FLACC and Ramsay evaluation in the emergence and reach bed, painkiller was administered FLACC > 4. Results: 121 patients, K group: 52.8%, group F: 47%, age: 47 ± 26.38 months, anesthetic time: 100.22 ± 38.7 min. Cardiovascular variables without intergroup difference in relation to time. Analgesia requirement at six hours in the K group vs F 10 hours. FLACC emergence mild to 86.8%; 49% K group and 37% F group (p = 0.02), 92% FLACC minor in bed, group K 52% and 40.4% F group (p = 0.002). At six hours FLACC > 4 K group (p = 0.002). Degree of sedation to extubation is lower in group K (p = 0.03). Conclusions: Ketamine preserves hemodynamic stability, decreases agitation and pain until the first six hours after procedure; so it can be used as adjuvant anesthetic in catheterizations safely.

6.
Arch. cardiol. Méx ; 76(supl.2): S100-S106, abr.-jun. 2006.
Article in Spanish | LILACS | ID: lil-568838

ABSTRACT

Artificial oxygen carriers may be grouped into two categories: Hemoglobin-based solutions and perfluoro-chemical based emulsions. Allogenic erythrocyte transfusions represent a limited resource and are associated with adverse events such as acute transfusion reactions, transmission of infectious diseases, immunosuppression and postoperative infections. Although [quot ]artificial blood[quot ] is not yet a clinical reality, several temporary [quot ]artificial oxygen carriers[quot ] are in late stage clinical development.


Subject(s)
Humans , Blood Substitutes , Cardiac Surgical Procedures , Oxygen , Fluorocarbons , Hemodilution
7.
Rev. mex. anestesiol ; 20(1): 26-31, ene.-mar. 1997. ilus
Article in Spanish | LILACS | ID: lil-225062

ABSTRACT

Durante los procedimientos quirúrgicos con circulación extracorpórea el método de hemoconcentración por el principio de ultrafiltración sanguínea fue empleado para controlar hemodilución en 250 pacientes. Un dispositivo de fibra hueca y un hemoconcentrador especial fue empleado. La cantidad de ultrafiltrado recibido de un paciente varió entre 2600 ml, con una media de 1825 ñ 800 ml. La hemoconcentración por el principio del método de ultrafiltración es relativamente simple, seguro, y efectivo para el control de la hemodilución durante la circulación extracorpórea. El empleo de este método no se acompaña por alteraciones significativas en la homeostasis. Este método puede ser recomendado para uso de rutina en operaciones a corazón abierto que ameriten circulación extracorpórea


Subject(s)
Humans , Male , Female , Extracorporeal Circulation , Thoracic Surgery , Hemofiltration
8.
Rev. mex. anestesiol ; 19(3): 122-7, jul.-sept. 1996. ilus
Article in Spanish | LILACS | ID: lil-184138

ABSTRACT

Se estudiaron 20 pacientes para cirugía de puentes aortocoronarios, los cuales fueron divididos en dos grupos: Grupo I (10 pacientes; 8 masculinos y 2 femeninos), los cuales recibieron una solución conteniendo glucosa-potasio-insulina. El grupo II (control, 10 pacientes, 8 masculinos y 2 femeninos), los cuales recibieron una solución Hartman Todos fueron monitorizados con electrocardiograma (derivación DII - V5), línea arterial, catéter en arteria pulmonar y en el seno coronario, frecuencia cardiaca, presión arterial media, gasto cardiaco y sus derivadas. Así mismo electrolitos, glucosa sanguínea y lactos en el seno coronario; efectuándose mediciones: basal, 5, 15, 30 y 60 minutos después de iniciada la infusión. Los cambios fueron analizados para detectar cualquier cambio usando la prueba de Wilcoxon y t de student pareada. Encontrándose cambios significativos en el grupo 1 al aumentar el gasto cardiaco, índice cardiaco, v menor producción de lactatos en el seno coronario, comparadas al grupo control. En conclusión de acuerdo a los resultados obtenidos en este estudio creemos que la solución polarizante puede ser usada en el paciente coronario con efectos benéficos hemodinámicos y sin complicaciones


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Potassium/administration & dosage , Solutions/administration & dosage , Solutions/therapeutic use , Glucose/administration & dosage , Insulin/administration & dosage , Myocardial Revascularization/methods
9.
Rev. mex. anestesiol ; 19(3): 128-45, jul.-sept. 1996. tab, ilus
Article in Spanish | LILACS | ID: lil-184139

ABSTRACT

Actualmente existe un incremento en el número de pacientes cardiópatas sometidos a cirugía no cardiaca. Sin embargo, la evaluación con la finalidad de poder predecir con mayor seguridad el riesgo a que estos se encuentran sometidos. Una exitosa evaluación y tratamiento del paciente cardiopata llevado a cirugía no cardiaca, requiere de un cuidadoso trabajo en equipo y comunicación entre el paciente, médico de primer contacto, anestesiólogo y cirujano. En esta revisión, se encuentran descritos ciertos factores y predictores de riesgo, así como también algunos algoritmos recientes, basados en los datos observacionales colectados y la opinión de los expertos más calificados, todo ello con la finalidad de involucrar al anestesiólogo en el cuidado preoperatorio, transoperatorio y postoperatorio del paciente con enfermedad cardiaca sometido a cirugía no cardiaca


Subject(s)
Humans , Risk Groups , Preoperative Care , Cardiovascular System/drug effects , Cardiovascular System/physiopathology , Risk Factors , Morbidity , Heart Diseases/surgery , Intraoperative Complications/etiology , Anesthesia , Myocardial Infarction , Heart Failure/etiology , Risk Assessment
10.
Rev. mex. anestesiol ; 18(4): 181-5, oct.-dic. 1995. tab
Article in Spanish | LILACS | ID: lil-164628

ABSTRACT

Se estudiaron 40 pacientes portadores de estenosis mitral, confirmada por cateterismo cardiaco y/o ecocardiografía transtorácica, programados para remplazo valvular mitral, los cuales semonitorizaron con electrocardiograma (DII), línea arterial, así comocatéter de flotación en arteria pulmonar. Registrándose las siguientes constantes hemodinámicas: Frecuencia Cardiaca (FC), presión arterial media (PAM), presión arterial pulmonar (PAP), presión capilar pulmonar (PCP), presión venosa central (PVC) y Gasto Cardiaco (GC), calculándoce Volumen Latido (VL), Indice sistólico (IS), Resistencias Vasculares Sistémicas (VS), Indice Trabajo Ventricular Izquierdo (ITVI), Resistencias Vasculares Pulmonares (RVP) y Producto presión-frecuencia (PPF). Se estímulo de ninguna índole se administró clorhidrato de esmolol en infusión a dosis de 450 µg/kg/min durante 15 min, tiempo en el cual se realizaron las mediciones antes mencionadas; básales (sin esmolol) y a los 3, 5, 10 y 15 minutos de iniciada la infusión, obteniéndose resultados significativos en el gasto cardiaco, índice cardiaco, frecuencia cardiaca, volumen latido,índice sistólico e índice de trabajo de ventricular izquierdo así como en las resistencias vasculares sistémicas y producto presión-frecuencia


Subject(s)
Adult , Middle Aged , Humans , Male , Female , Preoperative Care , Monitoring, Intraoperative , Drug Monitoring , Tachycardia, Ventricular/drug therapy , Adrenergic beta-Agonists , Mitral Valve Stenosis/surgery , Mitral Valve Stenosis/drug therapy , Atrial Fibrillation/drug therapy , Heart Rate
11.
Rev. mex. anestesiol ; 18(4): 189-93, oct.-dic. 1995. tab
Article in Spanish | LILACS | ID: lil-164630

ABSTRACT

Se estudiaron 39 pacientes con diferentes cardiopatías congénitas programados para corrección total de la misma bajo circulación extracorporea, administrándose anestesia balanceada con halogenado e infusión de clorhidrato alfentanyl en diferentes tiempos durante el acto anestésico quirúrgico, monitorizandose electrocardiograma de superficie, presión arterial invasiva, presión venosa central, tomándose muestras sanguíneas arteriales para verificar concentraciones plasmáticas de alfentanyl así mismo las variables hemodinámicas para correlacionar dichas muestras; dichos tiempos de medición fueron control, 3 min, incisión de piel, esternotomía, circulación extracorporea, cierre de esternón y fin de la cirugía; concluyéndose que las dosis administradas provee adecuada anestesia, así mismo se conserva estabilidad hemodinámica. Obteniéndose concentraciones plasmáticas adecuadas de anestesia cuando dichos niveles fueron de 192-303 ng/ml


Subject(s)
Child , Humans , Male , Female , Alfentanil/administration & dosage , Alfentanil/pharmacology , Alternism , Monitoring, Intraoperative , Drug Monitoring , Heart Defects, Congenital/surgery , Extracorporeal Circulation , Hemodynamics , Halothane/administration & dosage
12.
Arch. Inst. Cardiol. Méx ; 56(2): 147-55, mar.-abr. 1986. tab
Article in Spanish | LILACS | ID: lil-46453

ABSTRACT

Debido a numerosos informes existentes en la literatura media relacionados con las complicaciones del catéter de Swan-Ganz, efectuamos este estudio prospectivo de 120 inserciones de este catéter en 119 pacientes que ameritaron monitorización hemodinámica trans y postoperatoria en cirugía cardiovascular. En todos los casos, la colocación del catéter se efectuó inmediatamente después de la inducción anestésica por punción percutánea de la vena yugular interna usando la técnica de Seldinger modificada, tomando como referencia las curvas de presión intracavitarias hasta llegar a la posición de cuña pulmonar. Se investigó el tiempo de coloración, tiempo de uso, complicaciones de la punción, dificultad y complicaciones en la inserción, complicaciones torácicas y pulmonares, asa y nudo del catéter, infección en el sitio de punción y septicemia por el catéter. Resultados: múltiples punciones en 15 casos (12.5%); punción de carótida en 8 (6.6%); hematoma 14 (11.6%); dificultad para canular ventrículo derecho 8 (6.6%) y arteria pulmonar 32 (26.6%); imposibilidad para obtener posición de cuña 13 (10.8%); formación de asa del catéter 3 (2.5%); extrasístoles auriculares 30 (25%); taquicardia auricular 4 (3.3%); extrasístoles ventriculares 73 (60.8%); incidencia de arritmia en general 67.5%, ninguna de gravedad. Todas estas complicaciones fueron menores, sin peligro para la vida del paciente. Sólo en 2 casos (1.6%) hubo una complicación mayor (infarto pulmonar ambos, que tampoco comprometieron la vida del paciente) hubo 20 casos (16.6%) que cursaron sin complicación alguna. No hubo mortalidad por el catéter. Los resultados de este estudio demuestran que las complicaciones del uso del catéter de flotación pulmonar son mínimas en relación con los beneficios obtenidos en el manejo de estos pacientes


Subject(s)
Child , Adolescent , Adult , Middle Aged , Humans , Male , Female , Cardiac Catheterization , Heart Diseases/surgery , Intraoperative Care , Monitoring, Physiologic , Postoperative Care , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL